Hose selection for the conveyed medium, pressure, temperature and installation requirements.

Download product datasheet No public pricing. Configuration and availability confirmed by quotation.

Need help matching this part?
Speak to our technical team

SPECIFY WITH CONFIDENCE

Get the right configuration.

Final specifications, compatibility and availability are confirmed against your selected part and operating conditions.

01

Medium and concentration

02

Inside diameter and length

03

Pressure or vacuum and temperature

04

End connections and electrical requirements

CONFIGURATION DATA

Nonconductive EPDM coolant hose —7997 series.

7997-series nonconductive EPDM coolant hose with E-glass outer protection. 500°C denotes external radiant exposure, not conveyed-fluid temperature. Select coolant temperature, radiant exposure duration and electrical requirements separately. A nonconductive compound does not establish an assembly dielectric certification.

Part codeConfigurationId mmOd mmWorking pressure barMin bend radius mmWall constructionmax radiant temperature c (°C)
7997.025EPDM/E-glass soft-wall furnace coolant hose253910.0310Soft wall500
7997.032EPDM/E-glass soft-wall furnace coolant hose324810.0384Soft wall500
7997.038EPDM/E-glass soft-wall furnace coolant hose385810.0465Soft wall500
7997.051EPDM/E-glass soft-wall furnace coolant hose517110.0570Soft wall500
7997.063EPDM/E-glass soft-wall furnace coolant hose638310.0655Soft wall500
7997.076EPDM/E-glass soft-wall furnace coolant hose769610.0770Soft wall500
7997.102EPDM/E-glass soft-wall furnace coolant hose10212210.0980Soft wall500
CONFIGURATION DATA

Nonconductive EPDM coolant hose —7997 series — construction & conditions.

7997-series nonconductive EPDM coolant hose with E-glass outer protection. 500°C denotes external radiant exposure, not conveyed-fluid temperature. Select coolant temperature, radiant exposure duration and electrical requirements separately. A nonconductive compound does not establish an assembly dielectric certification.

ParameterSpecification
TubeRed or white nonconductiveEPDM
ReinforcementPolyester cord
Cover500g/m2 E-glass cloth impregnated with EPDM
Max roll length m20
Fluid temperature limitNot provided by exact table; external radiant-exposure value must not be used as fluid temperature
Dielectric test standardNot supplied
CONFIGURATION DATA

Nonconductive EPDM coolant hose —7997 series.

7997-series nonconductive EPDM coolant hose with E-glass outer protection. 500°C denotes external radiant exposure,not conveyed-fluid temperature. Select coolant temperature,radiant exposure duration and electrical requirements separately. A nonconductive compound does not establish an assembly dielectric certification.

ParameterSpecification
TubeRed or white nonconductiveEPDM
ReinforcementPolyester cord
CoverEPDM-impregnated500g/m2 E-glass cloth
Fluid temperature limitRequires selected assembly confirmation
Heat exposure scoperow500C maximum radiant temperature is external exposure only; no duration/flux condition supplied